Benefon TWIG INBOX Instrukcja Użytkownika Strona 53

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 107
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 52
MPTP | MPTP commands 53
Trigger type 7
Length: 90...104 characters
Command*
Part number*
Trigger type
Service state
Mode*
Battery level*
Position source*
Position format*
Position*
Time stamp*
4 1 5 1 1 1 1 1 4 1 4 1 3 1 1 1 24 1 19 1
!TRR _ 01/01 _ 1 _ 1 _ norm _ 075% _ gps _ 1 _ N68.28.43,9
E027.27.02,4
_ 20.10.2003
14:37:09
_
Speed*
Heading*
Message number
7 1 6 1 3…9
081km/h _ 114deg _ 3/10
The special fields of the command are as follows:
Field Description Range
Trigger type Trigger type of the tracking process, which
sent the report. Cf. section 4.2.1.4.
7
Service state Activity of tracking process. Value 1 should
be used, as the tracking process is active.
0…1
Current speed For a speed tracking process (trigger type
4), this field holds the current speed of the
terminal, in kilometers per hour.
0…999 (km/h)
Message number The message number of the report and the
total number of messages to be expected.
The first number is the message’s order
number and the number after the slash
character is the total number of messages to
be expected.
If the message order number or total number
of messages becomes more than 9999,
0000 is used in the field.
If the total number of messages cannot be
calculated 0000 is used in the field. This
case happens with tracking which does not
have stop trigger.
0000….9999 /
0000….9999